Measuring Equipment

Anemometers
Vector A100LK / LM
- Windspeed range: 0.2m/s to 75+ m/s (146Kts)
- Temperature range: -30° to 70°C
- Supply Voltage: 4.75V to 28V DC
- Power consumption: max 1.3mA
- Output Signal: Pulse (0V / 4V)
- -A100LK 10Hz per Knot
- -Α100LM 10Hz per m/s

Vector A100K / Μ
- Windspeed range: 0.2m/s to 75+ (146Kts)
- Temperature range:-50°C to +70°C
- Supply Voltage:10V to 30V DC
- Power consumption: 30mA at 12V DC
- Output Signal: Pulse (0V / 4V)
- -Α100L: 10Hz per Knot
- -Α100M: 10Hz per m/s

NRG#40C
- Windspeed range: 1 m/s to 96 m/s
- Temperature range: -55°C to 60°C
- Output voltage: max 12V peak to peak (at 60 Hz)
- Output Signal: low level AC with frequency proportional to windspeed.

NRG#40H
- Windspeed range: 1 m/s to 96 m/s
- Temperature range: -55°C to 60°C
- Supply Voltage:5 V to 24 V DC
- Power consumption: max 9mA
- Output Signal: Pulse with frequency proportional to wind speed.

THIES FIRST CLASS (with heating)
- Windspeed range: 0.3 to 75m/s
- Temperature range: -50°C to +80°C
- Supply Voltage:3.3V to 24V DC
- Output Signal: Pulse proportional to wind speed.
- Heating operating voltage: 24 V DC/AC
- Heating power: 25W.

THIES FIRST CLASS
- Windspeed range: 0,3 to75m/s
- Temperature range: -50°C to +80°C
- Supply Voltage: 3.3V to 24V DC
- Output Signal: Pulse proportional to wind speed.

Wind Vanes
NRG#200M
- Sensor range: 360°, continuous rotation.
- Threshold 1m/s.
- Temperature range: -40°C to +60°C
- Supply voltage: 4.5V to 15V DC
- Output Signal : Analog potentiometer DC

W200P/L
- Sensor range: 360°, continuous rotation.
- Threshold 0.5m/s.
- Temperature range: -30°C to 70°C
- Supply voltage: 1V to 5V DC
- Power consumption: max 10 mA (50μA προτ.)

2EN WSV
- Signal type: Analog Output 0 to 5V or digital (serial COΜ) 0 to 359.9°
- Survival speed: 85m/sec
- Operational Temperature: -20 °C to 50 °C
- Power supply voltage: 5V to 30V DC
- Power supply current: <3mA max

THIES 4.3151.10.020
- Range: 0 to 360°
- Precision: ±1°
- Response characteristics: threshold <0.5m/s in range 10°
- Operational speed: up to 75m/s
- Survival speed: 85m/s for up to 30min
- Operational temperature: -50 °C to 80 °C.
- Power supply: 3.3V to 12V DC

Thermometers
Vector PT100-T351PX
- Sensor range: -50°C to +70°C.
- Supply voltage: 1V έως 5V DC ή διακοπτόμενο DC
- Power consumption: 1mA max
- Output Signal: Linear-analog

NRG#110S
- Sensor range: -40°C to 52.5°C
- Supply voltage: 5V to 12V DC
- Power consumption: 0.3mA max
- Output Signal: Linear-analog

PT100 Istos Renewables (New)
- Sensor range: -50° to +60°C
- Supply voltage: 1V to 5V DC or interrupted DC
- Power consumption: 1mA max
- Output Signal: Linear-analog

Barometric pressure sensors
NRG#BP20
- Sensor range:15 kPa to 115 kPa
- Temperature range: 10°C to 50°C full accuracy
- Supply voltage: 7V to 35V DC
- Power consumption: 15mA max. (8 mA optional)

DRUCK LTD RPT410V
- Sensor range: 59.2 kPa to 110 kPa
- Temperature range: -40°C to 60°C
- Supply voltage: 9.5V to 25VDC
- Power consumption: 6mA

BARON
– Range: 150~1150mbar.
– Precision: +/- 15 mbar maximum non-correctable offset.
– Linearity: 0.1 % maximum
– Electrical time constant : 15 ms
– Power supply: 7 ~ 35 VDC, 15 mA max.
– Construction materials: Aluminium Cover 115 x 65 x 30 mm

Temperature/relative humidity sensors
RH: MP101 ROTRONIC AG +protective cage (calibrated)
- Sensor range: 0 to 100% RH
- Temperature range: -40°C to +60°C
- Supply voltage: 4.8V to 30.0V DC
- Output Signal: 0 to 1V DC linear
- Power consumption: <10mA
- Response time: 10sec.

THYGRO SDI-12
- Operational temperature: -40°C to +90°C.
- Precision:
<±1.8% RH (from 0 to 80% RH)
±0.2°C (from 0 to 60°C) - Output signal:
– Analog output of temperature and humidity, chosen at 3 areas: 0 to 1V DC, 0 to 2.5V DC, 0 to 5V DC
– Digital output SDI-12 of temperature and humidity.

Relative humidity sensors
NRG RH-5
- Sensor range: 5 to 95% RH
- Temperature range: -40ºC to +54ºC
- Supply voltage: 10V to 36V DC
- Output Signal: linear analog 0V to 5V
- Power consumption: 1.2mA at 12V

Sunlight radiation Sensors
SP LITΕ (pyranometer)
- Spectral range: 0.4 to 1.1 µm wave range
- Temperature range: -30ºC to +70ºC
- Response time: < 1sec
- Output Signal: linear-analog 0V to 5V

Si-RS485TC-T-MB
- Radiation measurement: up to 1500 W/m2
- Measurement of temperature cell: -40 to 90 °C
- Temperature of operation: -35 to 80 °C
- Weight: Approximately 0.4 kg
- Measurement uncertainty:
– Radiation: ±5 W/m2 ± 2.5% of MV
– Cell temperature: 1.0 K for a span -35 to 80 °C

Gradiometers
Symmetron
- Sensor range: 3D
- Supply voltage: 6 to 18VDC,
- Power consumtion: 8mA
- Output signal (elevation): 0~2.5V or 0~5V, -90° to +90°
- Output signal (azimuth): 0~2.5V or 0~5V, 0° to +360°

Time switches
Istos Renewables
- Features: Interrupts once per day to auto reset the modem
- Supply voltage: 9 to 15VDC
- Power consumption: 8mA
- Temperature range: -50 ºC to +70 ºC

Dataloggers
Stylitis-41
- Manufacturer: SYMMETRON
- Features: Stand-alone, battery-operated Datalogger, Simple menu structure. Compatibility with most types of sensors. Samples once per second. Software included free: Stylitis Explorer.
- Temperature range: -30ºC to +70ºC
- Analog inputs: 4 of 12 bit each.
- Counting inputs: 3, of 16 bit each.
- Data stored to Compact Flash up to 2GB.

Stylitis-10
- Manufacturer: SYMMETRON
- Features: Stand-alone, battery-operated Datalogger, Simple menu structure. Compatibility with most types of sensors. Samples once per second. Software included free: opton and auto connect.
- 7 input voltage / current / temperature / digital.
- Inputs counters: 1 or 2.
- Recording in internal memory Flash 4MB.
- Data can be sent via e-mail.
- Possibility of publication:
- with GSM /GPRS modem.
- with GSM /GPRS modem & GPS module.
- with Ethernet.
- with WiFi.
- Ability to connect sensors MODBUS RTU (RS-485) and SDI-12.

Stylitis-101
- Manufacturer: SYMMETRON
- Features: Stand-alone, battery-operated Datalogger, Simple menu structure. Compatibility with most types of sensors. Samples once per second. Software included for free: Stylitis Explorer.
- Analog inputs: 6 of 12 bit each. Option of extending up to 18 inputs.
- Counting inputs: 6 (3+3 additional), of 16 bit each.
- Data stored to internal memory Flash of 512 KBytes or up to 2 GBytes external compact Flash

CR-800
- Manufacturer: Campbell Scientific
- Features: Stand-alone, battery-operated Datalogger, Simple menu structure. Compatibility with most types of sensors. Samples once per second.
- Software required: LoggerNet or PC400 (not free). Fully programmable by scripting.
- Maximum Scan Rate: 100 Hz
- Analog inputs: 3 differential (or 6 single-ended), of 13 bits each
- Counting inputs: 6, of 24 bits each
- Digital inputs: 4 terminals that can be programmed either as digital or counting inputs
- Data stored to internal memory Flash of 4 MB.
- Ability of sending data via email

CR1000X
- Manufacturer: Campbell Scientific
- Features: Stand-alone, battery-operated Datalogger, Simple menu structure. Compatibility with most types of sensors. Samples once per second.
- Software required: LoggerNet or PC400 (not free). Fully programmable by scripting.
- Maximum Scan Rate: 1000 Hz
- 8 differential (or 16 single-ended), of 24 bits each
- 2 (P1-P2) of 32 bits each
- 8 terminals (C1-C8) configurable for digital input and output
- Data stored to internal memory Flash of 4 MB + 128 MB flash
- Ability of sending data via email

KINTECH Orbit 360
- Frequency channels: 10 physical frequency channels and 6 extra channels
- Analog channels: 15 physical analog channels and 8 extra channels for digital sensors
- Sampling rate: 1 Hz
- Recording interval: 1, 5 or 10 minutes
- Standard deviation: Precision 0.01 m/s
- Internal memory: EEPROM
- Removable memory: SD / MMC, Micro SD

Rain Gauges
Istos Renewables RainMan Mk1
Mechanical parts
- Aluminum alloy tipping bucket
- Magnetic reed switch IP67
- Stainless steel enclosure/body
- Funnel top: galvanized metal sheet – bottom orifice: plastic ABS
- Stainless steel filter.
Specifications
- Resolution: 0.13mm per tip
- Output: rectangular pulse per switch close
- Dimensions: Φ190mm x 550mm
- Weight: 4kg